Features of EWN-Y-A (+EFS) series
- The Auto-air vent valve eliminates the gas-lock problem with continuance bleeding liquid and gas constructions.
- A precise flow measuring per stroke and a feed back control enable precise chemical dosing, mean while the bleeding system is normally difficult to keep precise dosing.
- The system can also bleed gas out as short time as possible, even if setting discharge flow is small.
Philosophy of the Non-Gas Lock system
The bleeding system takes gas and liquid out from the pump chamber. However, dosing capacity is kept setting volume due to feed back control with the flow signal.
When large volume of gas comes into the pump chamber, pump discharge capacity will be “zero” until bleeding the gas out. The feed back control increase pump operating speed, thus gas bleeding time will be in short time.
When the gas bleeding is completed, the pump discharge volume returns to the setting valve immediately by the feed back control with the flow signal.
Specifications of pump
Discharge capacity range | 30 – 110 mL/min |
---|---|
Max. discharge pressure range | 0.7 – 1.0 MPa |
Main materials | PVC, PTFE |
Stroke rate | 1 – 360 spm |
Liquid temperature range | 0 – 40°C |
Viscous liquid | Please contact us for details. |
Specifications of controller
Operation mode | MAN control | Operation at MAN speed | 0.1 – 100.0% (1 – 360 spm) |
---|---|---|---|
Feedback control | 0.1 – 999.9 mL/min, 0.001 – 59.994 L/H, 0.001 – 15.828 GPH | ||
EXT control | ANA.R (analogue rigid) | 4 – 20, 20 – 4, 0 – 20, 20 – 0 mA (proportional operation with stroke rate) | |
ANA.V (analogue variable) | 2 point setting (set point 1 and 2, flow rate or stroke rate) | ||
BATCH (batch operation) | 0.1 – 99999.9 mL, 0.001 – 99.999 L, 0.001 – 26.385 G | ||
PLS (pulse operation) | 2 point setting (set point 1 and 2, flow rate or stroke rate) | ||
Input | Buffer pulse | No voltage contact or open collector | |
Analogue | 0 – 20 mADC (input resistance 220 Ω) | ||
STOP/Pre-STOP (level sensor) | No voltage contact or open collector | ||
AUX | No voltage contact or open collector | ||
Interlock | No voltage contact or open collector | ||
Batch Start/Stop | No voltage contact or open collector | ||
Pulse | No voltage contact or open collector | ||
Output | OUT1 | No voltage contact (mechanical relay) 250 VAC at 3A (resistance load), Enable or disable the alarms of STOP, Pre-STOP, Interlock, Batch, Out of measurement and Poor flow | |
OUT2 | No voltage contact (photoMOS) 24 VAC/DC at 0.1 A, Enable or disable the alarms of STOP, Pre-STOP, Interlock, Batch, Out of measurement and Poor flow or Synchronous output (sensor/pump) | ||
Analogue | 4 – 20 mADC (The max. load resistance is 500 Ω) | ||
Buffer memory | Nonvolatile memory | ||
Power voltage | 100 – 240 VAC 50/60 Hz |